Two Pressure Levels for More Natural Breathing
Unlike single-level pressure devices, the DF-925S supports separate inspiratory and expiratory pressure settings. It delivers a higher prescribed pressure during inhalation and transitions to a lower pressure during exhalation, helping provide synchronized bilevel respiratory support throughout each breathing cycle. In spontaneous breathing modes, the device detects the transition between inhalation and exhalation and switches between the preset pressure levels accordingly.
IPAP
EPAP
Made for Powerful Bilevel Support
The DF-925S BiPAP machine is designed to provide stable and comfortable pressurized airflow, with adjustable pressure up to 25 cmH₂O. It also features advanced ST mode with backup respiratory support and VGPSS mode with adjustable target tidal volume.
So the device is ideal for treating patients with sleep apnea and respiratory insufficiency, like OSA (Obstructive Sleep Apnea), CSA (Central Sleep Apnea), COPD (Chronic Obstructive Pulmonary Disease), OHS (Obesity Hypoventilation Syndrome) etc.
Noise
Weighs
ST Mode with Backup Rate Support (BUR)
In ST mode, a backup respiratory rate can be set from 3 to 50 breaths per minute (BPM). If the user’s spontaneous breathing rate falls below the prescribed setting, the DF-925S delivers timed bilevel pressure support to help maintain the configured breathing rhythm.
By supporting both inhalation and exhalation, the device may help reduce breathing effort and promote more effective ventilation during periods of insufficient spontaneous breathing.
Backup Rate
Inspiratory Time
VGPSS Target Tidal Volume Support
VGPSS mode provides an additional therapy option for users who require a clinician-configured target tidal volume. The target tidal volume can be adjusted from 150 to 1500 mL in 50 mL increments, allowing the therapy settings to be adapted to individual ventilation requirements. In this mode, respiratory rate and inspiratory time can also be configured. The respiratory rate is adjustable from 3 to 50 BPM, while inspiratory time can be set from 0.3 to 4.0 seconds.
Target Tidal Volume
Adjustment Increment
Respiratory Rate
Inspiratory Time
Adjustable Ramp for a Gentler Therapy Start
Air pressure can be built up from a lower and easier level after the treatment begins when the user is still awake. Then pressure will be increased gradually and very comfortably to the target level after the user falls asleep. The ramp time can be set from 0 to 60 minutes in 5-minute increments. Users can select a shorter or longer ramp period according to the settings recommended by their healthcare professional.
Ramp Time
Adjustment Increment
Integrated Heated Humidifier
The integrated heated humidifier adds moisture to the airflow before it reaches the mask, helping reduce the dryness that some users may experience during extended therapy sessions. The humidification level can be adjusted from 33℃ to 55℃, allowing users to select an appropriate level according to environmental conditions and personal comfort.
Water Chamber
Temperature Range
Level
Preheat Time
Real-Time Therapy Monitoring
During therapy, the DF-925S displays important treatment and ventilation information directly on its color screen. This allows users and qualified healthcare professionals to view key operating data without needing a separate mobile application or external display.
The monitoring interface can show: VT(Tidal Volume), LV(Leak Volume), MV(Minute Ventilation), RR(Respiratory Rate), Current Working Mode, Treatment Pressure, Initial Pressure, Humidification Status, Ramp Status
Smart Configurable Safety Alerts
The DF-925S includes multiple configurable alerts designed to identify important changes in therapy or equipment operation. Available alert settings include: High Pressure Alert, Low Pressure Alert, High Breathing Rate Alert, Low Breathing Rate Alert, Low Minute Ventilation Alert, Apnea Alert, System Leak Alert, Mask or Tubing Disconnection Alert, Power Failure Alert.
Multiple Options for Your Convenience
-
Expiratory Relief
Choose from 0–5 pressure relief levels to reduce pressure during exhalation, helping each breath feel smoother and more comfortable during therapy.
-
Easy to Operate
Navigate settings easily using the clear display, rotary control knob and one-button operation, with adjustable brightness and screen sleep time.
-
Auto Start/Stop
Automatically starts therapy when you breathe into the mask and stops after removal, while manual Start/Stop control remains conveniently available.